Sciences in Cold and Arid Regions ›› 2017, Vol. 9 ›› Issue (4): 420–424.doi: 10.3724/SP.J.1226.2017.00420

• ARTICLES • 上一篇    

Analysis of bearing capacity of pile foundation in discontinued permafrost regions

JiLiang Wang1, ChenXi Zhang1, XinLei Na2   

  1. 1. Heilongjiang Province Academy of Cold Area Building Research, Harbin, Heilongjiang 150060, China;
    2. Golder Assocuates Inc., Anchorage, Alaska 99507, United States of America
  • 收稿日期:2017-04-10 修回日期:2017-05-10 发布日期:2018-11-23
  • 通讯作者: JiLiang Wang, Heilongjiang Province Academy of Cold Area Building Research. No. 60, Qingbin Road, Harbin, Heilongjiang 150060, China. Tel: +86-451-86304197; E-mail: wangjiliang@sohu.com E-mail:wangjiliang@sohu.com

Analysis of bearing capacity of pile foundation in discontinued permafrost regions

JiLiang Wang1, ChenXi Zhang1, XinLei Na2   

  1. 1. Heilongjiang Province Academy of Cold Area Building Research, Harbin, Heilongjiang 150060, China;
    2. Golder Assocuates Inc., Anchorage, Alaska 99507, United States of America
  • Received:2017-04-10 Revised:2017-05-10 Published:2018-11-23
  • Contact: JiLiang Wang, Heilongjiang Province Academy of Cold Area Building Research. No. 60, Qingbin Road, Harbin, Heilongjiang 150060, China. Tel: +86-451-86304197; E-mail: wangjiliang@sohu.com E-mail:wangjiliang@sohu.com

摘要: Piles are the main building foundation in permafrost regions. Thawing the permafrost foundation would have a negative effect on a pile, and may cause damage to the building. This paper focuses on the effects of negative friction force due to the melt of permafrost, and presents four calculated methods for bearing capacity of a pile. An engineering station was taken as an example, where the lengths of a pile were compared based on four methods. Finally, quick field load tests were carried out, and some meaningful conclusions are presented. Thus, these analytical results can be used to design a pile for permafrost regions.

关键词: discontinued permafrost, pile, bearing capacity, negative friction force

Abstract: Piles are the main building foundation in permafrost regions. Thawing the permafrost foundation would have a negative effect on a pile, and may cause damage to the building. This paper focuses on the effects of negative friction force due to the melt of permafrost, and presents four calculated methods for bearing capacity of a pile. An engineering station was taken as an example, where the lengths of a pile were compared based on four methods. Finally, quick field load tests were carried out, and some meaningful conclusions are presented. Thus, these analytical results can be used to design a pile for permafrost regions.

Key words: discontinued permafrost, pile, bearing capacity, negative friction force

Andersland OB, Ladanyi B, 2004. Frozen Ground Engineering. 2nd ed. New York: John Wiley and Sons, Inc.
Chen ZY, Li GY, Yu QH, et al., 2013. Study of the thermal stability of cast-in-place pile foundations of the Qinghai-Tibet DC Transmission project in permafrost regions. Journal of Glaciology and Geocryology, 35(5): 1209–1218. DOI: 10.7522/j.issn.1000-0240.2013.0136. (in Chinese)
Ding JK, Han LW, Xu BK, et al., 2011. Permafrost and Railway Engineering. Beijing: China Railway Publishing House, pp. 351–352.
Foriero A, Ladanyi B, 1991. Design of piles in permafrost under combined lateral and axial load. Journal of Cold Regions Engineering, 5(3): 89–105. DOI: 10.1061/(ASCE)0887-381X(1991)5:3(89).
Heydinger AG, 1987. Piles in permafrost. Journal of Cold Regions Engineering, 1(2): 59–75. DOI: 10.1061/(ASCE)0887-381X(1987)1:2(59).
Jin HJ, Yu WB, Chen YC, et al., 2005. (Differential) frost heave and thaw settlement in the engineering design and construction of oil pipelines in permafrost regions: a review. Journal of Glaciology and Geocryology, 27(3): 454–464. DOI: 10.3969/j.issn.1000-0240.2005.03.021. (in Chinese)
Ministry of Housing and Urban-Rural Development of People's Republic of China. 2012. JGJ 118-2011 Code for design of soil and foundation of buildings in frozen soil region. Beijing: China Building Industry Press.
Sego DC, Biggar KW, Wong G, 2003. Enlarged base (belled) piles for use in ice or ice-rich permafrost. Journal of Cold Regions Engineering, 17(2): 68–88. DOI: 10.1061/(ASCE)0887-381X(2003)17:2(68).
Sheshpari MM, Khalilzad S, 2016. A review on permafrost geotechnics, foundation design and new trends. International Journal of Engineering Research and General Science, 4(10): 59–71.
Tsytovich NA, 1975. The Mechanics of Frozen Ground. New York: McGraw-Hill Book Company.
Wang RH, Wang W, Chen YF, 2005. Model experimental study on compressive bearing capacity of single pile in frozen soil. Journal of Glaciology and Geocryology, 27(2): 188–193. DOI: 10.3969/j.issn.1000-0240.2005.02.006. (in Chinese)
Xu Y, Zhang LM, 2007. Settlement ratio of pile groups in sandy soils from field load tests. Journal of Geotechnical and Geoenvironmental Engineering, 133(8): 1048–1054. DOI: 10.1061/(ASCE)1090-0241(2007)133:8(1048).
Yang CS, He P, Niu FJ, 2002. The state and progress of study on frozen ground thaw settlement. In: The Sixth International Symposium on Permafrost Engineering. Lanzhou, Gansu, China: Chinese Geographical Society, pp. 82–87.
Zhou XG, Wang XM, Xu C, et al., 2008. Study on method comparison between quick and slow load in pile static test. Hydrogeology and Engineering Geology, 35(3): 35–38. DOI: 10.3969/j.issn.1000-3665.2008.03.009.
Zubeck H, Aleshire L, Hagood S, 2012. Pile load tests in permafrost using spiral legs to support hot ice No. 1 drilling platform. In: 13th International Conference on Cold Regions Engineering. Orono, Maine, United States: American Society of Civil Engineers, pp. 1–11. DOI: 10.1061/40836(210)52.
[1] JianKun Liu, TengFei Wang, Zhi Wen. Research on pile performance and state-of-the-art practice in cold regions[J]. Sciences in Cold and Arid Regions, 2018, 10(1): 1-11.